Home > Products > load cell and accessories > Single Point Load Cell >

IPW12C 50 kg to 750 kg Single Point Load Cell for platform scale

IPW12C 50 kg to 750 kg Single Point Load Cell for platform scale

IPW12C 50 kg to 750 kg Single Point Load Cell for platform scale
CategoriesSingle Point Load Cell
AlbumView larger image
BrandInntronic
ModelIPW12C
TypeSingle Point Load Cell
MaterialAluminum
Capacity50 kg to 750 kg
Sensitivity2.0
AccuracyC3
Input impedance300 ... 500
Output impedance330 ... 430 (Option 6: A = 410 Ω
Zero balance0±0.1
Applicationplatform scale
Protection classIP67
FOB portSHANGHAI
Terms of PaymentL/C
Update Time2019-07-22
Detail Information

IPW12C 50 kg to 750 kg Single Point Load Cell 



Type

IPW12C

Accuracy class1)

C3; C3MR

Number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2))

kg

50

75

100

150

200

250

300

500

635

750

Minimum LC verification interval (vmin)

Accuracy class C3

g

10

10

20

20

50

50

50

100

100

100

Temperature effect on

zero balance (TK0)

Accuracy class C3

 

% v.

Cn /

10 K

 

±0.0280

±0.0186

±0.0280

±0.0186

±0.0350

±0.0280

±0.0233

±0.0280

±0.0221

±0.0186

Minimum LC verification interval (vmin)

Accuracy class C3MR

g

5

5

10

10

20

20

20

50

50

50

Temperature effect on

zero balance (TK0)

Accuracy class C3MR

% v.

Cn /

10 K

 

±0.0140

±0.0093

±0.0140

±0.0093

±0.0140

±0.0112

±0.0093

±0.0140

±0.0110

±0.0093

Max. platform size

mm

800 x 800

Sensitivity (Cn)

mV/V

2.0±0.2 (Option 6: A = 2mV/V±0.1%)

Zero balance

0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40  [+68 ... +104]

−10 ... +20  [+14 ... +68]

% v.

Cn /

10 K

 

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

Ω

300 ... 500

Output resistance (R0)

330 ... 430 (Option 6: A = 410 Ω±0.2 Ω)

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

15

Max. excitation voltage

15

Insulation resistance (Ris) at 100 VDC

> 2

Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]

Service temp. range  (Btu)

−10 ... +50 [+14 ... +122]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150

Lateral load limit (Elq), static

% of

Emax

300

Breaking load (Ed)

300

Deflection at Emax (snom), approx.

mm

< 0.5

Weight (G), approx.

kg

2.4

Protection class according to

EN 60 529 (IEC 529)

 

IP67

Material: Measuring element

Coating

Cable sheath

 

Aluminum

Silicone rubber

                                                                                 PVC






 1) In accordance to OIML-R60 with P     = 0.7LC

2) Max. eccentric load according to OIML R76

3) The sum of data for Non-linearity, Hysteresis error and TC Span meets the requirements of OIML R60

4) Eccentric error according to OIML R76


Special features 

− OIML-R60 approval 

Max. Capacities: 50 kg...750 kg 

Off center load compensated 

(OIML R76) 

Meets EMC standards 

(EN 45 501) 

6-wire circuit 

Optional: 

Reduced minimum LC verification interval (vmin) for multi range applications 

Explosion-proof versions 

Different cable lengths 

Aligned output, suitable for connection in parallel



Please send your message to us
*Email
Tel
*Title
*Content

Agree to use terms of service