Home > Products > load cell and accessories > Single Point Load Cell >

High Stability Industrial Load Cells Dust Prevention For Weight - Lost Weighter

High Stability Industrial Load Cells Dust Prevention For Weight - Lost Weighter

High Stability Industrial Load Cells Dust Prevention For Weight - Lost Weighter
CategoriesSingle Point Load Cell
AlbumView larger image
BrandInntronic
ModelISP12
patternSingle Point Load Cell
capacity60kg 120kg 300kg
output2mv/v
materialAluminum
applicationWeight-lost Weighter
Interchangeable brandHBM
IP protectionIP65
accuracy gradeC3
Hysteresis0.0166
Non-linearity0.0166
Update Time2019-07-16
Detail Information
ISP12 60kg 120kg 300kg Single Point Load Cell for Weight-lost Weighter


Special features

  •  Accuarcy class C3 with OIML-R60 test report
  •  Max.capacities:60kg,120kg,300kg
  •  Special for Weight-lost Weighter
  •  Max.permissible 70% off-center load error
  •  IP65 degree pf protection




TypeISP12
Maximum capacity (Emax)kg60120300
Minimum LC verification intervalg102030

Temperature effect on

zero balance (TK0)

% v.

Cn /

10 K


±0.0233
Sensitivity (Cn)²mV/V2±0.2
Zero balance±0.05

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40℃ [+68 ... +104℉]

−10 ... +20℃ [+14 ... +68℉]

% v.

Cn /

10 K


±0.0175

±0.0177

Hysteresis error (dhy)3)% of Cn±0.0166
Non-linearity (dlin)3)±0.0166
Minimum dead load output return (DR)±0.0166
Off center load error4)±0.0233
Max.platform sizemm300X300450X450600X600
Input resistance (RLC)Ω300 to 500
Output resistance (R0)300 to 500
Reference excitation voltage (Uref)V5
Nominal range of excitation voltage (BU)1...15
Max. excitation voltage15
Insulation resistance (Ris) at 100 VDC> 2
Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]
Service temp. range (Btu)−10 ... +50 [+14 ... +122]
Storage temp. range (Btl)−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150
Breaking load (Ed)

% of

Emax

300
Deflection at Emax (snom), approx.mm< 0.5
Material Aluminum
Weight (G), approx.kg0.07

Protection class according to

EN 60 529 (IEC 529)

 IP65


 